Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/21/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 11/17/2005 | FRAMING | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspection Items 2 and 10 from prior inspection not done Anchor bolts required within 12" of plates splices and ends Nail protect a/c cable You must pay a reinspection fee for not complying with prior write ups and multiple inspections you have 5 days to pay refee |
|
| 11/15/2005 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) NO APPROVED PLANS ON SITE 2) ITEMS 2, 8 AND 10 FROM PRIOR INSPECTION NOT DONE 3) STOPPED INSPECTION 4) NEXT FAILURE, WILL REFEE |
|
| 11/08/2005 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) PROVIDE PLANS WITH CITY OF TUCSON APPROVAL ON ENGINEERING PAGES S1 THRU SD4 2) 1" CLEARANCE REQUIRED BETWEEN WATER HEATER "B" VENT AND COMBUSTIBLE MATERIAL 3) EDGE NAILED WIRES NOT ALLOWED 4) KITCHEN COUNTER OUTLET CIRCUIT CANNOT HAVE OUTLETS IN LIVING ROOM 5) 5?/AD3 REQUIRES 1" STAIR BULL NOSE 6) 8" STAIR RISER EXCEEDS 7 3/4 MAX LIMIT 7) STAIR RISERS CANNOT 8) FIRE BLOCK STAIRS 9) FIRE STOP DUCT CHASE 10) A/C MAKE UP AIR CANNOT BE WITHIN 10 FEET OF SEWER ? 11) STOPPED INSPECTION-TO MANY ITEMS |