Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM02564
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/21/2005 | FRAMING | Approved | IVRS - Inspection :* | |
12/14/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FHA STRAP GAS MAIN RISER 2) NEED RED HEAD EAST OF GAS MAIN AND 3" ABS AT KITCHEN 3) SHIM HEADERS WHERE NEEDED, TRIMMERS AND CRIPPLES 4) FIREBLOCK LIVING PASS THROUGH CHASE 5) LOW TRUSS IN FRONT BED (WRONG TRUSS) 6) PROVIDE 1" TO WATER HEATER B-VENT AND COLLAR 7) NEED WATER AND DWV 8) NEED GABLE X BRACING 9) CORRECT IMPENDED MECH ACCESS 10) CORRECT 2ND FLOOR SMOKEY LOCATIONS 11) NEED PATCHING AND SEALING 12) PROVIDE TOP TO BOTTOM GIRDER TRUSS TRANSFERANCE |