Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM02559
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/12/2005 | FRAMING | Approved | IVRS - Inspection :* | |
10/05/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BLK AND STRAP H20 LINES KITCHEN H20 HTR 2) BACK PITCH ON TOILET ARM, ALSO SHOWER 5' LIMIT ON 2" TRAP ARM, BATHROOM ABOVE GARAGE TO HOUSE DOOR 3) GAS BOND NOT CONNECTED 4) H.D. NOT INSTALLED 1ST FLOOR BATH 5) BLK MECH 6) CLIP WITH TALON 2ND FLOOR H20 AT TUB 7) CHANGE OUT LU 26, AT SINGEL GIRDER FOR AN HUS TYPE 16D'S |