Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/26/2005 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 08/25/2005 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) SUPPORT M/C CABLE WITHIN 12" OF BOXES AND 6' 2) PROTECT M/C CABLE IN CHANEL OR MOVE OUT 3) OK PVC UNDER SLAB-NOTE 360 DEGREE IN RUN |