Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit: T05CM02538

Parcel: 136261280

Inspection Status: Approved

Inspection History: PLUMBING - ROOF DRAINS

Date Description Inspector Results Comments
11/23/2005 PLUMBING - ROOF DRAINS Approved IVRS - Inspection :*RECEIVED LETTER FROM ENGINEER APPROVED SUPPLY BACKFLOW CERTIFICATIONS
10/12/2005 PLUMBING - ROOF DRAINS Partial Approval IVRS - Inspection :*WATER TEST OK. PROVIDE LETTER FROM ARCH OR ENGINEER GIVING SIZE OF ROOF DRAINAGE PIPING.
10/06/2005 PLUMBING - ROOF DRAINS Partial Approval IVRS - Inspection :* WATER TEST (2) SETS 4" RAIN DRAIN & OVERFLOW RAIN DRAINS OK
SUPPORT HORIZONTAL PIPING AT 4' INTERVALS & CHANGE OF DIRECTION.
PROVIDE STAMPED LETTER FROM ENGINEER ON ROOF DRAIN SIZING