Permit: T05CM02526

Parcel: 140377170


Addresses:

6904 S MARTLET DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
08/16/2005 FRAMING Approved IVRS - Inspection :*
08/15/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) EDGE NAILED WIRES NOT ALLOWED
2) 2 X BLOCKING MISSING PER 6/SD3
3) NO DWV WATER TEST
08/12/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FB GARAGE
2) NO DWV WATER TEST
3) PROVIDE HEADERS FOR INTERIOR BEARING WALLS
4) 2 X BLOCKS MISSING AT DBL SHEAR WALL 6/SD3
5) HTT16 REQUIRE 5/8" ANCHOR BOLTS
6) EDGE NAILED WIRES AT SERVICE PANEL NOT ALLOWED