Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T05CM02522
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/18/2005 | ELECTRIC - INTERMEDIATE | Approved | ||
10/04/2005 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :*OK FRAME WALLS EXCEPT BATHROOMS | |
10/03/2005 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :*PROTECT CABLE & FLEX AT CROSS BRACES SUPPORT M/C CABLE WITHIN 12" OF BOX NOT OFF OF CONDUITS SUPPORT CONDUIT WITHIN 3' OF PVC FITTING AND AT TOP SUPPORT M/C CABLE WITHING 12" OF PANEL FINISH BATHROOM. |
|
10/02/2005 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
09/29/2005 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* SUPPORT AND PROTECT M/C CABLE IN CHANEL AND AT TOP PLATES PROPERLY SUPPORT M/C CABLE PREVENT DIE ELECTRIC CONTACT UNCOVER BATH FIXTURE BOX. FILL UNUSED OPENING IN FIXTURE PLANS CALL FOR CONDUIT. PLEASE PROVIDE A LETTER AUTHORIZING USE OF FLEX AND M/C CABLE WHERE IS BATH EXHAUST FAN? UNDERGROUND INSTALLED WITHOUT INSPECTION. UNCOVER IF TO BE USED. WALLS COVERED WITHOUT INSPECTION. PLEASE UNCOVER TO INSPECT. NOTE. VDV CABLEING TO BE AS PER 725.2 & 6, 800.2 2 & 6 |