Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM02517
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/09/2006 | FRAMING | Approved | IVRS - Inspection :* | |
01/06/2006 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) FIRE STOP AT CEILING NOT INSTALLED |
|
12/29/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) FIRESTOP AT CEILING. USE METAL IF WANT-WERE THE FLUE ENTER THE BOTTOM OF CHORD OF CEILING TRUSS. INSTALL A METAL BLOCK AROUND FLUE TO OSB TO STOP FIRE AND DRAFT FROM GETTING INT CEILING ATTIC AREA |
|
12/23/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) MARKED ON FLOOR AT FIREPLACE FRONT ENTRY, ALL SW2 INTERIOR SHEARWALLS BATHROOM NEXT TO KITCHEN |
|
12/21/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) KEEP H20 PEX LINES 12" FROM CAN LIGHTS 2) LOOSE (BOTTOM PLATE) AT TOILET 3) RECEPTACLES NOT ALLOWED UNDER COUNTER OVERHANGS 4) INTERIOR SHEARWALLS REQUIRE ANCHOR BOLTS AT 32" ON CENTER 5) GAS NOT RUN TO FIREPLACE 6) FIREPLACE, FIRESTOP TO GO AT DROP CEILING 7) ROMEX NOT CONNECTED, AT CEILING FRONT DOOR, MORE NAILING AT FRONT DOOR DROP CEILING 8) BACKING AT TUB SIDES 9) SECURE TOP PLATE FRONT BEDROOMS 10) LOOSE BOTTOM PLATE EAST BATHROOM |
|
12/13/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) COMPLETE STUCCO LATH AND ALL TRADES PRIOR TO INTERMEDIATE INSPECTIONS |