Permit: T05CM02517

Parcel: 141015630

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM02517

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
01/09/2006 FRAMING Approved IVRS - Inspection :*
01/06/2006 FRAMING Not ready for Inspection IVRS - Inspection :*
1) FIRE STOP AT CEILING NOT INSTALLED
12/29/2005 FRAMING Partial Approval IVRS - Inspection :*
1) FIRESTOP AT CEILING. USE METAL IF WANT-WERE THE FLUE ENTER THE BOTTOM OF CHORD OF CEILING TRUSS. INSTALL A METAL BLOCK AROUND FLUE TO OSB TO STOP FIRE AND DRAFT FROM GETTING INT CEILING ATTIC AREA
12/23/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
1) MARKED ON FLOOR AT FIREPLACE FRONT ENTRY, ALL SW2 INTERIOR SHEARWALLS BATHROOM NEXT TO KITCHEN
12/21/2005 FRAMING Partial Approval IVRS - Inspection :*
1) KEEP H20 PEX LINES 12" FROM CAN LIGHTS
2) LOOSE (BOTTOM PLATE) AT TOILET
3) RECEPTACLES NOT ALLOWED UNDER COUNTER OVERHANGS
4) INTERIOR SHEARWALLS REQUIRE ANCHOR BOLTS AT 32" ON CENTER
5) GAS NOT RUN TO FIREPLACE
6) FIREPLACE, FIRESTOP TO GO AT DROP CEILING
7) ROMEX NOT CONNECTED, AT CEILING FRONT DOOR, MORE NAILING AT FRONT DOOR DROP CEILING
8) BACKING AT TUB SIDES
9) SECURE TOP PLATE FRONT BEDROOMS
10) LOOSE BOTTOM PLATE EAST BATHROOM
12/13/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
1) COMPLETE STUCCO LATH AND ALL TRADES PRIOR TO INTERMEDIATE INSPECTIONS