Permit: T05CM02515

Parcel: 128100550


Addresses:

250 S WILLIAMS BL


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T05CM02515

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
07/14/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
REVISED APPROVED PLANS ON SITE.
07/12/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
WAITING ON REVISED CITY APPROVED PLAN FOR PAST NOTES.
06/29/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) CALLED IN BY MISTAKE
06/16/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. UNABLE TO LOCATE PLUMBER.
2. G.C NOT IN TRAILER.
06/16/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
RPS INSTALLED IN MECHANICAL ROOM.
UNIONS REQUIRED.
PLATFORM REQUIRED FOR ASSEMBLY OVER 5'
04/18/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
WATER DISTRIBUTION OVERHEAD & IN WALL 4TH LEVEL OK
EXCEPT MECH ROOM
03/07/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
2" GREASE TRAP VENT THRU ROOF OK
3RD LEVEL WATER DISTRIBUTION OVERHEAD/IN WALL OK
WASTE & VENT THRU ROOF ALL LEVELS OK EXCEPT DRAINAGE FOR COOLING TOWER AREA.
WATER DISTRIBUTION 1ST THRU 3RD LEVELS OK
03/01/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
SUPPORTS FROM 2/24/06 INSPECTION OK
1ST & 2ND LEVEL WASTE & VENT THRU ROOF SOUTHEND BREAKROOM & AHV FLOOR SINKS WATER TEST OK PER 2/7/06 PLAN STAMPPED BY KEN CAWTHORNE SERVING AS RED LINE. SHALL BE CITY APPROVED. KITCHEN WATER PIPING OK
ELEVATOR PITS PUMP DRAINAGE OK
PLEASE REFERENCE CHAPTER 7 SECTION 709.0 FOR DRAINAGE REQUIREMENTS FOR COOLING TOWER DRAINAGE. 94 UPC
02/24/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
2ND LEVEL RESTROOMS, LAVS, URINALS, NORTHEND BREAKROOM INTERMEDIATE OK
1. NEED TO SEE SUPPORT ON VERTICALS & REVENTS IN STOOL & URINAL WALLS. 2" GREASE TRAP VENT FROM GREASE TRAP THRU TO 4TH FLOOR AT 10' WATER TEST OK
02/17/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
WATER TEST WASTE & VENT THRU ROOF ALL AREAS OK
1. NEED VIEWING & REVISION OF SOUTH END SYSTEM DETAIL 5 P.3.1
02/16/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
WATER TEST WASTE & VENT THRU ROOF URINALS WALL OK
WATER TEST WASTE & VENT 1ST THRU 3RD REVENT ELEVATOR STEEL WALL OK
WATER TEST WASTE & VENT KITCHEN AREA THRU ROOF OK
02/14/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
AS INITIALED ON PLAN IN TRAILER
AS INITIALED IN PLAN IN TRAILER
IN WALL WATER PIPING ON 1ST & 2ND FLOOR OK
WATER TEST WASTE & VENT THRU ROOF FOR WOMEN'S RESTROOM LAVS & WOMENS RESTROOM LAVS AND JANITOR CLOSETS OK
1. WILL REQUIRE REVISION FOR DELEATION OF FLOOR SINKS ON 1ST THRU 3RD FLOORS.
1ST FLOOR WOMENS 101 AND MENS 103 RESTROOM WATER TEST ONLY OK
1ST FLOOR THRU ROOF BREAKROOMS AND DRINKING FOUNTAINS WATER TEST WASTE AND VENT OK