Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T05CM02511
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/23/2006 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* *NOTE* INSTALL ALL EQUIPMENT COVERS - NOW! ADD EXTRA STRAP FOR EACH SECTION OF EMT ON ROOF FOR HOUSE LIGHTING RACEWAY. |
|
03/20/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* #98 - OPEN GROUND DINING RECEPT, PANEL NOT CORRECTLY MARKED, REMOVE UNUSED CONNECTOR IN AC DISCONNECT. #111 - NEED AC SERVICE OUTLET, OPEN GROUND ON DINING RECEPT. PANEL NOT CORRECTLY MARKED. #108 - INSTALL COVERS ON DEVICES, PROVIDE CORRECTLY MARKED PANEL COVER. #107 - INSTALL DEVICE COVERS #104 - NOT READY 103, OPEN BULB IN CLOSET, LAUNDRY LIGHT NOT WORKING OUTLETS TO THE RIGHT OF KITCHEN SINK NOT WIRED CORRECTLY MAKE SURE PANEL IS CORRECTLY MARKED 100 - FRONT BEDROOM OUTLETS NOT WORKING ALSO, 1. ALL UNITS NEED SERVICE OUTLETS FOR ROOF EQUIP. 2. ALL UNITS NEED TWO 20 AMP APPLIANCE CKT'S WITH NOTHING ELSE ON THEM - INCLUDIG DISHWASHER & DISPOSAL DISH & DISP NEED SEPARATE CKT. 3. ALL WIRING FOR HOUSE LIGHTS NEED TO BE PROPERLY SECURED SUPPORTED AND WEATHERPROOF 4. YOU WILL NEED TO PAY A RE-INSPECTION FEE PRIOR TO FINISH APPROVAL. |
|
03/16/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. GO THROUGH ALL UNITS TO MAKE SURE THEY ARE READY FOR INSPECTION. PANEL DIRECTORIES PROPERLY MARKED, 2 WIRE OUTLETS AS NEEDED K.O. SEALS AS NEEDED, 2 SMALL APPLIANCE CKTS |
|
03/15/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. NO OUTSIDE GFI OUTLETS 2. USE LISTED 2 WIRE NON GROUNDING RECEPTS ON UNGROUNDED CIRCUITS |
|
01/25/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FINISH UNITS 2) PROVIDE ROOF ACCESS 3) INSTALL UNIT NUMBERS 4) CALL FOR FINAL WHEN COMPLETE 5) WASHER CKT TO BE DEDICATED ? NEC 210.11 |