Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T05CM02507
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/12/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1. ALL CORRECTIONS MADE OK. 2. PLUMBING FINAL OK. 3. OK FOR C OF O PENDING ANY OTHER INSPECTION. |
|
05/09/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* UNIT 83 T&P PLUGGED, UNION LEAKING T&P TO TERMINATE WITHOUT THREADS KIT. SINK LEAKING CORRECT KINK IN CW FLEX TO WH SUPPORT & SECURE EXPANSION TANK SECURE VENT W/GALVANIZED SHEET METAL SCREWS |
|
05/08/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* #82 -- SEE NOTES FROM 5/4/06 #81 -- SEE NOTES FROM 5/4/06 INSPECTION STOPPED. |
|
05/07/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* ONLY ONE SLIP NUT AFTER P-TRAP |
|
05/04/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* ONLY ONE SLIP NUT ALLOWED ON THE OUTLET SIDE OF THE TRAP -- INSPECTION STOPPED. |
|
05/03/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. YARDWATER OK TO COVER 2. FINAL NOT READY FOR INSPECTION |
|
05/01/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. CALL IN AND HAVE APPROVED ALL REQUIRED INSPECTION PRIOR TO CALLING FINAL. |
|
04/28/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* CLEAN OUT PLUGS SHALL BE LISTED TO ACCEPT SCREW FROM CLEANOUT COVER, DRILLING ABS IS NOT PERMITTED. EXTERIOR HB'S REQUIRE VACUUM BREAKERS DW DRAIN HOSES SHALL BE SECURED AS HIGH AS POSSIBLE AND IN NO CASE LESS THAN 2" BELOW FLOOD LEVEL OF SINK T&P DRAINS PLUGGED! |