Permit: T05CM02507

Parcel: 11615194B

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T05CM02507

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
05/12/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
1. ALL CORRECTIONS MADE OK.
2. PLUMBING FINAL OK.
3. OK FOR C OF O PENDING ANY OTHER INSPECTION.
05/09/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
UNIT 83 T&P PLUGGED, UNION LEAKING
T&P TO TERMINATE WITHOUT THREADS
KIT. SINK LEAKING
CORRECT KINK IN CW FLEX TO WH
SUPPORT & SECURE EXPANSION TANK
SECURE VENT W/GALVANIZED SHEET METAL SCREWS
05/08/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
#82 -- SEE NOTES FROM 5/4/06
#81 -- SEE NOTES FROM 5/4/06
INSPECTION STOPPED.
05/07/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
ONLY ONE SLIP NUT AFTER P-TRAP
05/04/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
ONLY ONE SLIP NUT ALLOWED ON THE OUTLET SIDE OF THE TRAP -- INSPECTION STOPPED.
05/03/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. YARDWATER OK TO COVER
2. FINAL NOT READY FOR INSPECTION
05/01/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. CALL IN AND HAVE APPROVED ALL REQUIRED INSPECTION PRIOR TO CALLING FINAL.
04/28/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
CLEAN OUT PLUGS SHALL BE LISTED TO ACCEPT SCREW FROM CLEANOUT COVER, DRILLING ABS IS NOT PERMITTED.
EXTERIOR
HB'S REQUIRE VACUUM BREAKERS
DW DRAIN HOSES SHALL BE SECURED AS HIGH AS POSSIBLE AND IN NO CASE LESS THAN 2" BELOW FLOOD LEVEL OF SINK
T&P DRAINS PLUGGED!