Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/13/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 09/12/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) AB @ HD SW CORNER NOT INSTALLED OK TO START SHEET ROCK, LEAVE AREA OPEN FOR INSPECTION |
|
| 09/09/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* AB @ HD SW CORNER |
|
| 09/06/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO RISER AT PANEL, NO TEMP GFCI, NO BREAKER 2) FIRE BLOCK DROP CEILING AT LAUNDRY AND NAIL PROTECT DRYER VENT 3) STRAP TOP PLATE AT FRONT BED ROOM 4) GAPS BETWEEN SOFFIT AND FIRE BLOCKS AT REFRIDGERATOR AREA 5) CONDENSATE LINES FOR FAV NOT CONNECTED 6) STUD IN SOUTH EAST B/R NOT NAILED AND SECURE ROMEX WITHIN 8" FROM BOX |