Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/05/2006 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 01/04/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED POSITIVE DRAINAGE FROM HOUSE ON SOUTH SIDE 2) REVERSE POLARITY RECEPTACLE S.E. CORNER GREAT ROOM 3) RECEPTACLE AT SOFTENER IN GARAGE SHOULD BE SINGE, NOT DUPLEX 4) NO RECEPTACLE IN ATTIC |
|
| 12/27/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLETE GRADING 2) OPEN GROUND KITCHEN GFI 3) SINGLE RECEPTACLE FOR DEDICATED IN GARAGE 4) NO ATTIC LIGHT 5) NO ELECTRIC GREAT ROOM 6) COMPLETE CLEANOUTS 7) RAISE OVERFLOW MAIN A/C DRAIN |