Permit: T05CM02450

Parcel: 118082100

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM02450

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
09/23/2005 FRAMING Approved IVRS - Inspection :*
09/22/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
09/21/2005 FRAMING Partial Approval IVRS - Inspection :*
1) LATH, PENETRATIONS NOT SEALED AND LATH AROUND WINDOWS, NOT COMPLETE AND AROUND ELEC PANEL
2) PARTIAL, MECH NOT PER PLAN (WAITIN ON REVISION)
09/20/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) (LATH) SEAL ALL PENETRATIONS
2) SW2 SHEE MISSING AT GARAGE
3) FIRE BLOCK F/P
4) SEAL ALL PENETRATIONS FROM 1ST TO 2ND FLOOR
5) BLOCK REGISTER AT UPSTAIRS BATH
6) FIRE BLOCK STRINGERS
7) WATER LINE NEED 12" CLEARANCE FROM CAN LIGHT
8) MISSING BLOCKING PANEL AT DOWNSTAIRS BED ROOM
9) STRINGERS MISSING HANGERS
10) ST 2115 MISSING PER DETAIL 3D-1
11) MECHANICAL NOT PER PLAN
09/09/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL PROTECT ELEC IN GARAGE
2) FIRE BLOCK MISSING AT ENTRY CLOSET
3) BLOWN FIRE BLOCK AT DINING ROOM
4) NAIL PROTECT ROMEX FROM OUTSIDE AT DINING ROOM
5) FIRE BLOCK BOTH SIDES OF HOOD VENT
6) SHIM HEADERS
7) FIRE PLACE NOT INSTALLED
8) FIRE BLOCK FIRE PLACE
9) FIRE BLOCK STRINGERS
10) NAIL PROTECT ELECTRIC AT STAIR HAND RAIL
STOPPED INSP