Inspection History Details
Inspection Status: Approved
Inspection History: ROOF NAILING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/09/2006 | ROOF NAILING | Approved | IVRS - Inspection :* | |
| 01/05/2006 | ROOF NAILING | Partial Approval | IVRS - Inspection :* 1) OK TO LOAD ROOF 2) DETAIL 502 SHOWS CONTINOUS 2X TOP OF WALL FOR SHEETROCK NAILING AND TRUSS NAILED TO PLATE 12" ON CENTER 3) TRUSS REPAIR OK |
|
| 12/19/2005 | ROOF NAILING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED PER PAPERWORK TURNED IN BY INSPECTOR R. FREIDINGER |
|
| 12/16/2005 | ROOF NAILING | Partial Approval | IVRS - Inspection :* 1) OK TO DRY IN, FIX BROKEN TRUSSES |
|
| 12/14/2005 | ROOF NAILING | Partial Approval | IVRS - Inspection :* 1) OK TO DRY IN ROOF DON'T LOAD UNTIL TRUSSES FIXED 2) CHECK TWO DAMAGED TRUSSES 3) COMPLETE GARAGE SHEAR DETAIL 502 AT GARAGE WALL |
|
| 12/13/2005 | ROOF NAILING | Partial Approval | IVRS - Inspection :* 1) NAILING APPROVED 2) NO TRUSS DRAWINGS ON SITE 3) PLAN CALLS FOR SHEAR BRACING DETAIL 502 |
|
| 12/12/2005 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) EXTERIOR ONLY 2) CHECK ENTIRE ROOF 3) 2 ROWS MISSED NORTH SIDE GARAGE 4) NO TRUSS DRAWINGS 5) BLOCK RIDGE IN GARAGE AT HIP 6) NAIL OFF HIP HANGERS AT GIRDER TRUSS |