Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T05CM02412
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/22/2005 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
12/15/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLETE PRIOR ITEMS #4 AND 8 |
|
12/13/2005 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* 1) REPAIR S/R GARAGE TO HOUSE 2) NO STREET ADDRESS 3) INSTALL VACUUM BREAKER ON IRRIGATION 4) ONE SCREW ON DEAD FRONT COVER STRIPPED 5) BEDROOM 2 AND 3 ARC FAULT BREAKER DOES NOT TEST 6) REPAIR COVERS OUTSIDE RECEPTACLE 7) REMOVE FLEX BEHIND STOVE AND CAP PIPE OR VALVE 8) EXHAUST FAN POWDER ROOM INOPERABLE 9) INSTALL RECEPTACLE AND SWITCH AT SINK 10) OPEN GROUND RECEPTACLE LEFT OF SINK 11) OPEN GROUND RECEPTACLE UNDER COUNTER L/R SIDE |