Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM02412
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/05/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
08/08/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL OFF FRIEZE BLKS, AT ROOF WEST MAIN AND GARAGE 2) CHECK LATEAL BRACING, TRUSSES 3) NEED PLANS AND PERMIT, TRUSS DRAWINGS 4) TWO NAILS IN EACH WIND BRACE 5) WIND BRACE MISSIGN GARAGE WEST 6) CRACK IN OSB EAST SIDE 7) STRAP FRONT COLUMN 8) TIE SHEARWALLS TO TOP CHORD OF TRUSS |