Date Description Inspector Results Comments
10/18/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
1) TRUSS REPAIR DETAIL SENT TO RECORDS
10/12/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) OK TO LATH
2) FIX TRUSS TOP CHORD, BOTH SIDES OF TRUSS FRONT NEED TRUSS REPAIR
10/10/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
10/06/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL ROOF
2) CLIP TRUSSES AT FRONT PARAPET TO TRUSS
3) REAR SHEAR NOT NAILED AT SHOWER
4) TIE 1ST TO 2ND FLOOR REAR ENTIRE LENGTH
5) FLOOR NOT NAILED
10/04/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ROOF COVERED WITHOUT INSPECTION
2) MISSING WIND BRACING, STUD TO STUD TO TRUSS TIES
3) GARAGE TRUSS TIES MISSING AT FRONT OVER BEAM, NAIL SHORT HIP TRUSSES
4) ATTACH ALL PLATE JOINTS, NAIL OFF ALL MAS CONNECTORS
5) FLASHING BACKING SHED ROOF FRONT TO VOLT WALL
6) MISSED NAILING ROOF 2 SPOTS IN FIELD AND NAIL OFF FRIEZE BLOCKS
7) REPAIR TRUSS NOTCHED FOR OUT RIGGERS NOT INSTALLED
8) CLIP FRONT PARAPET
9) NAIL CORNERS
10) NAIL OFF 2ND FLOOR DECK