Permit: T05CM02409

Parcel: 141017530

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM02409

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
11/03/2005 FRAMING Approved IVRS - Inspection :*
11/01/2005 FRAMING Partial Approval IVRS - Inspection :*
1) NEED DWV AND POTABLE H20 TEST
2) STRAP GAS LINE ATTIC
3) ELECTRIC FOR 2ND FLOOR BATH NOT COMPLETE
4) #4 SHEARWALL REQUIRES 1/2" DIAMETER A.B. AT 48" ON CENTER
5) 8D NAIL IN 1ST FLOOR LAV VERT/DRAIN
6) REPLACE DRYER DUCT
7) ROMEX TO 1ST FLOOR EXHAUST FAN UNDER STAIR
8) CONSULT WITH POST TENSION ENGINEER, REF 2" VENT FOR WEST TOILET AND SHOWER, CONC. CUT AT EDGE/PERIMETER FTG
7) STAPLE IN 1" H20 LINE AT H20 HTR
8) FREON LINE STAPLE KIT WALL