Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM02408

Parcel: 141017710

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM02408

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
08/16/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
08/15/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) OK TO DRY IN ONLY, 2ND FLOOR DECK IS NOT NAILED OFF
2) FINISH SHEAR JOINTS, THRU OUT
3) NEED WIND BRACE EAST WALL
4) MISSED ON SHEAR CLIP FRONT WALL
08/12/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) BLOCK ALL OSB TURNED PARALELL TO SUPPORTS
2) FINISH ALL SHEAR CLIPS
3) NAIL ENDS OF TRUSSES/FLOOR TO OSB BAND SEE PLAN
4) MISSING NAILING FRONT SHEAR
5) NAIL OFF FRIEZE BOARDS ROOF WEST SIDE
6) 2ND FLOOR DECK/FLOOR NOT SECURED