Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/16/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 08/15/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) OK TO DRY IN ONLY, 2ND FLOOR DECK IS NOT NAILED OFF 2) FINISH SHEAR JOINTS, THRU OUT 3) NEED WIND BRACE EAST WALL 4) MISSED ON SHEAR CLIP FRONT WALL |
|
| 08/12/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) BLOCK ALL OSB TURNED PARALELL TO SUPPORTS 2) FINISH ALL SHEAR CLIPS 3) NAIL ENDS OF TRUSSES/FLOOR TO OSB BAND SEE PLAN 4) MISSING NAILING FRONT SHEAR 5) NAIL OFF FRIEZE BOARDS ROOF WEST SIDE 6) 2ND FLOOR DECK/FLOOR NOT SECURED |