Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T05CM02403
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/03/2005 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* 1) TRENCH DRAIN WATER TEST OK |
|
07/25/2005 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) PIPE WRAPS OK 2) NEED TO VIEW TRENCH DRAIN INSTALL |
|
07/22/2005 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) WATER TEST ON ? SAND INTERCEPTOR OK INCLUDING VENT 2) OK FOR BACKFILL ON UNDERGROUND PIPING 3) NEED TO VIEW PIPE WRAPS PRIOR TO CONCRETE 4) NEED TO VIEW INSTALL TRENCH DRAIN WITH WATER TEST |
|
07/21/2005 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) 6 PSI AIR TEST UNDERGROUND FROM EXISTING 4" BLDG DRAIN STUB TO RESTROOM AND TO JUST BEFORE SAND/OIL INTERCEPTOR OK 2) NEED TO SEE TEST ON INTERCEPTOR FROM 2 WAY CLEANOUT AND UP STREAM OF INTERCEPTOR |