Permit: T05CM02387

Parcel: 10818716A


Addresses:

1765 E RIVER RD 1M


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T05CM02387

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
10/21/2005 PLUMBING - FINAL Approved IVRS - Inspection :*
10/20/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) SANITARY VENTS ON ROOF TO BE TERMINATED CORRECTLY AND PAINTED. IF WITHIN 10' OF AIR INTAKES TO BE 2' ABOVE
2) PROVIDE 3-GALV SCREWS AT EACH JOINT OF WATER HEATER VENT
3) PROVIDE 1" AIR GAP FOR ICE BIN DRAIN
4) PROVIDE ACCESS TO AIR ADDMITTANCE VALUE AT SINK IN WAITRESS STATION
5) SECURE WATER HEATER EXPANSION TANK
10/19/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*LEFT GAS CLEARANCE CARD AT METER
CONTRACTOR TO INSTALL SIGN: ANSUL VALVE ABOVE( EITHER ON CEILING TILE OR ON STAINLESS STEEL HOOD.
10/11/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*