Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/03/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 10/20/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) PARTIAL PENDING APPROVAL OF SW2 SHEAR AT DEN AND KITCHEN PANTRY 2) OK TO INSULATE |
|
| 10/19/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO TEST ON DWV'S 2) FIREBLOCK MISSING AT STRINGERS |
|
| 10/13/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED ON SITE |
|
| 10/12/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LATH NOT STAPLED 16" ON CENTER 2) REPLACE OVER NOTCHED BEARING STUDS THROUGHOUT HOUSE 3) SHIM HEADERS AND MOVE FIREBLOCKS UP TO DROPPED CEILING 4) DETAIL 34 S1-2 NOT PER PLAN 5) ELECTRIC WIRE HAS ELECTRIC TAPE WRAPPED. HAVE ELECTRICIAN CHECK AND INSPECT AT RETURN AIR AREAS 6) SHIM HEADERS WHERE NEEDED 7) BLOWN FIREBLOCK AT DEN 8) EXTERIOR BEARING STUD MISSING AT KITCHEN 9) PROVIDE 1/4" PER FOOT DROP AT ABS |
|
| 10/10/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LATH, LOOSE MESH AT GARGE, SOUTH SIDE OF GARAGE NOT COMPLETE, CHECK HOUSE B/F RECALL 2) NO PLAN/PERMIT |