Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T05CM02378
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/18/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 07/17/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 07/06/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE VACUUM BREAKERS ON HOSE BIBS 2. MAKE ALL FIXTURES WATER TIGHT. 3. WATER HEATER T&P DRAIN TO BE APPROVED FULL SIZE PIPING GRAVITY DRAIN TO DAYLIGHT. 4. PROVIDE CORRECT TAPPED CLEANOUT PLUGS & MACHINE SCREWS WITH COVERS FOR CLEANOUTS. 5. 2-WAY CLEANOUT TO BE TO GRADE WITH CORRECT TERMINTION. 6. PROVIDE PVC TRAP ADAPTERS FOR PVC PIPE FOR SINK LOCATIONS WITH CORRECT GLUE & PRIMER. 7. PAINT VENTS THRU ROOF TO PROTECT FROM SUN DAMAGE |