Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T05CM02378
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/02/2006 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
| 01/27/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*PARTIAL TO LEDGER LINE | |
| 01/26/2006 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* YOU DON'T HAVE VERTICALS IN OR BOND BEAM COMPLETED LET ALONE PA STRAPS. RECALL FOR TOMORROW 2. STAGGER LAP SPLICES IN BOND BEAM 3. NO SPLICES ALLOWED WITHIN 8' OF MCJ |
|
| 01/24/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*4' OK @ PARTY WALL |