Permit: T05CM02372

Parcel: 140378110


Addresses:

5881 E FANTAIL LN

Inspection Status: Partial Approval

Inspection History: FRAMING

Date Description Inspector Results Comments
12/01/2005 FRAMING Partial Approval IVRS - Inspection :*
1) PENDING MECH
2) APPROVED TO INSULATE
3) BROKEN WINDOW IN ?.R.
4) FRESH AIR INTAKE REQUIRES 10' MINIMUM CLEARANCE TO FURNACE EXHAUST
12/01/2005 FRAMING Approved IVRS - Inspection :*
11/23/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) COMPLETE STUCCO MESH NAILING 6" ON CENTER-MUST HIT STUDS
2) REPLACE BLOCKING AT WATER HEATER
3) 1" CLEARANCE TO COMBUSTIBLES AROUND B-VENT
4) WIRES RESTING ON B-VENT
5) SEAL 2ND FLOOR PENETRATIONS
6) PROTECT WIRES FROM GANG PLATE ON FLOOR TRUSS OVER KITCHEN
7) OUTLET BY CLEANOUT IN KITCHEN TO BE ON SMALL APPLIANCE
8) TIGHTEN AB'S THROUGHOUT
9) STOPPED INSPECTION-TOO MANY ITEMS