| 12/06/2005 | SHEET ROCK NAILING | Approved | IVRS - Inspection :* | |
| 12/05/2005 | SHEET ROCK NAILING | Cancelled | CANCELLED PER TIM OF K.B. HOMES #907-6040 | |
| 12/02/2005 | SHEET ROCK NAILING | Denied | IVRS - Inspection : The drywall is not nailed per code.| 175* 1) 2/SD2 NOT COMPLIED WITH AT GARAGE AND POWDER ROOM 2) SCREWS TO SHORT FOR 5/8" FIRE RATED DRYWALL USE 1 7/8" NAILS 3) 5/8" TYPE X DRY WALL REQUIRES 1 7/8" NAILS-SCREWS NOT ALLOWED |
|
| 12/01/2005 | SHEET ROCK NAILING | Not ready for Inspection | IVRS - Inspection :* | |
| 11/30/2005 | SHEET ROCK NAILING | Cancelled | CANCELLED PER TIM OF K.B. HOMES #907-6040 |