Permit: T05CM02371

Parcel: 140376560


Addresses:

6849 S HARRIER LP

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
10/12/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
10/10/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 2ND FLOOR P-1 SHEAR NOT NAILED
10/07/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ITEMS 3 AND 4 OF 10/06/05 INSPECTION NOT DONE
10/06/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) EAST SECOND FLOOR PLATE MUST BEAR ON FLOOR
2) CS20 STRAPS MISSING FRONT SHEAR 1/SD2
3) BLOCK AND NAIL P-3 SHEAR UNDER WINDOW
4) REAR 2ND FLOOR P-1 SHEAR NOT BLOCKED AND NAILED
10/03/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*