Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM02369
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/09/2006 | FRAMING | Approved | IVRS - Inspection :* | |
02/06/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REMOVE SCREW FROM DRYER VENT 2) MISSING 2" CLEANOUT AT POWDER ROOM AND DIRTY ARM EXTENDS MORE THAN 12" 3) BEDROOM 3 SMOKE DETECTOR NOT 36" FROM REGISTER 4) LATH SEAL ALL PENETRATIONS |
|
02/02/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) METAL BOXES NOT GROUNDED 2) LATH SEAL ALL PENETRATIONS 3) S.G.D. MISSING 4) NAIL PROTECT ABS AT LAUNDRY 5) MOVE ELECTRIC WIRES AWAY FROM GUSSETT PLATES 6) SEAL HOLE AT FLOOR ABOVE KITCHEN 7) NAIL PROTECT WATER LINE AT KITCHEN 8) LEAK AT 3" LINE AT ENTRY CLOSET 9) NAIL PROTECT COPPER LINE 10) STOPPED INSPECTION 11) HOUSE NOT WALKED BY SUPER |