Permit: T05CM02367

Parcel: 11205283F

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
10/04/2005 PLUMBING - INTERMEDIATE Approved 3" VTR IS OK IVRS - Inspection :*
09/21/2005 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ONLY 24 FIXTURE UNITS MAYBE RUN ON A 2" VENT
2) THE CROSS SECTIONAL AREA OF THE VENT THRU ROOF MUST EQUAL THE REQUIRED BLDG SEWER
3) RE-TEST THE SYSTEM
4) OVERHEAD WATER DISTRIBUTION IS OK
09/15/2005 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) GREASE INTERCEPTOR INSTALLATION IS OK
2) OK TO BACKFILL TRENCH
08/19/2005 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) TRAP PRIMERS/UNDERGROUND WATER SUPPLIES BLOCKOUTS AND CLOSET WRAPS OK
2) OK TO CONCRETE