Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/15/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 11/14/2005 | FRAMING | Cancelled | CANCELLED PER TIM (SUPER) OF KB HOMES #907-6040 | |
| 11/10/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. NO DWV WATER TEST 2. REVERSE PITCH HALL BATH LAV DIRTY ARM 3. BOTH SHEAR WALL NOT FRAMED AT 16" OC AND DOUBLE TOP PLATE COMPLY WITH 6/SD3 4. WATER SVC NOT CONNECTED - NOTE PLUMBING AND ELECTRIC WILL REQUIRE REMOVAL AT BOTH SHEAR WALLS. 5. KITCHEN COUNTER GFCI OUTLET CIRCUIT CANNOT HAVE LIVING ROOM OUTLETS ON THAT CIRCUIT |
|
| 11/09/2005 | FRAMING | Cancelled | CANCELLED PER TIM (SUPER) OF K.B. HOMES #907-6040 | |
| 11/09/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |