Permit: T05CM02362

Parcel: 110121000

Inspection Status: Approved

Inspection History: ELECTRIC - ABOVE CEILING

Date Description Inspector Results Comments
03/01/2006 ELECTRIC - ABOVE CEILING Approved IVRS - Inspection :*NEED LIGHTING CHANGES FOR FINAL
02/28/2006 ELECTRIC - ABOVE CEILING Not ready for Inspection IVRS - Inspection :*
1. SUPPORT WIRES NEEDED FOR RECESSED CAN
2. VDV CABLING TO BE SUPPORTED AS PER 725.6 & 800.6
3. MANUFACTURERS FIXTURE CLIPS TO BE EFFECTIVE USE ALL (4)
4. CLEAN EXCESS FOREIGN MATERIAL FROM INSIDE PANEL
5. DEVICES 8' AND BELOW TO BE INSTALLED OR BOXES PLATED
02/27/2006 ELECTRIC - ABOVE CEILING Not ready for Inspection IVRS - Inspection :*