Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
12/06/2005 ELECTRIC - FINAL Approved IVRS - Inspection :*
11/29/2005 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*DUCT WORK AND VENTS NOT INSTALLED AS DISCUSSED FOR CLEARANCES.OTHER ITEMS CORRECTED.
11/28/2005 ELECTRIC - FINAL Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
ALL UNITS: 1) MAX 30 AMP OVER CURRENT ON A/C'S
2) MINIMUM 50 AMP OVERCURRENT FOR RANGES
-------------------------------------------------------------------------------------------------
UNIT "A": 1) MARK PANEL DIRECTORY CORRECTLY
2) KITCHEN COUNTER OUTLETS NEED GFI PROTECTION
3) USE FAN RATED BOXES FOR CEILING FANS
4) INSTALL ARC FAULT BREAKER ON BEDROOM CKT'S
-------------------------------------------------------------------------------------------------
UNIT "B": 1) MARK PANEL DIRECTORY CORRECTLY
2) KITCHEN COUNTER OUTLETS NEED GFI PROTECTION
3) FURNACE CORD NEEDS TO BE SHORTENED AND CONNECTOR TIGHTEN AT J-BOX, ALSO HAS CONDUCTOR OUTSIDE OF J-BOX
4) SMOKE DETECTORS NEED TO BE INTER-CONNECTED
5) NEED ARC FAULT PROTECTION FOR BEDROOMS
6) USE FAN RATED BOXES FOR CEILING FANS
-------------------------------------------------------------------------------------------------
UNIT "C": 1) MARK PANEL DIRECTORY CORRECTLY
2) KITCHEN COUNTER OUTLETS NEED GFI PROTECTION
3) NEED ARC FAULT PROTECTION FOR BED CKT
-------------------------------------------------------------------------------------------------
UNIT "D": 1) KITCHEN COUNTER OUTLETS NEED GFI PROTECTION
2) MARK PANEL DIRECTORY CORRECTLY
3) SHORTEN FURNACE CORD
4) SMOKE DETECTORS TO BE INTER-CONNECTED
5) USE FAN RATED BOXES FOR CEILING FANS
6) PROVIDE ARC FAULT PROTECTION FOR BEDROOM CKT'S