Permit: T05CM02337

Parcel: 136140720

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM02337

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
09/29/2005 FRAMING Approved IVRS - Inspection :*
09/28/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL PROTECTION REQUIRED BOTH SIDES OF 3" WASTE LINE IN GARAGE WALL
2) NAIL PROTECT WIRES THROUGHOUT
3) TIGHTEN AB IN LIVING ROOM
4) SECURE SWITCH BOX AT ENTRY BOTH SIDES
5) FIREBLOCKS AROUND STAIRWAY LANDING TO HIGH
6) NAIL PROTECT 2" VENT TO ROOF BEHIND SHOWER 2ND FLOOR
7) SECURE WIRES 6" FROM BOX IN LOFT