Permit: T05CM02330

Parcel: 140383340

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
08/12/2005 FRAMING Approved IVRS - Inspection :*
08/11/2005 FRAMING Partial Approval IVRS - Inspection :*
1) NO DWV TEST
2) OK TO INSULATE
08/05/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL BANG PLATES WITHIN 1 1/2" OF STUD CACE PLUMBIN THRU STUDS THROUGHOUT
2) INSTALL BANG PLATES, ELECTRIC THRU STUDS LESS THAN 1 1/4" FROM STUD FACE THROUGHOUT
3) GANG PLATE TRUSS BEARING WEST WALL BATH INCORRECTLY INSTALLED
4) NO TEST DWV
5) HINGE BRACING GABLE ENDS REQUIRES 2 X BRACE AT MID SPAN WITH (2) 16D'S EACH CONNECTION (DETAIL 6/DT1)