Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/29/2005 | PLUMBING - INTERMEDIATE | Approved | PER PLUM FINAL | |
| 10/31/2005 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :*ROOM 247 & 361 TUBS & LAVS OK | |
| 10/27/2005 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :*WATER TEST UNDERGROUND 2" DRAIN FOR BAR SINK IN LOUNGE OK H20 PIPING TO SAME OK | |
| 10/25/2005 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999*ROOM 361 TUB FLOR SHALL HAVE STRUCTURE ENGINEER DETAIL REPAIR TO TGI FLOOR JOIST. BLAKE TEE IS A VERTICAL FITTING ONLY. DRAIN ARM IS ALLOWED TO HAVE ONLY (1) 90 DEGREE CHANGE OF DIRECTION. LEAVE A MESSAGE CONTACT PHONE NUMBER NO CONTRACTOR ON SITE.HAVE PLUMBING CONTRACTOR ON SITE AT NEXT INSEPCTION.! TGI JOIST REPAIR TO BE INSPECTED BY BUILDING INSPECTOR BEFORE PLUMBING SIGN OFF. HAVEYOIUR CITY APPROVED PLAN ON SITE. |
|
| 10/14/2005 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) ROOM 361 DWV ADPT FOR LAV DRAIN OK 2) PAY REFEE 3) PROVIDE TEST TO OVERFLOW HEIGHT ON TUBS TRIP LEVER CLOSED DOES NOT TEST TRAP AND DRAIN PIPING 4) USE APPROVED DWV MALE ADAPTER, SEE NOTES FROM 10/10/05 AND 10/11/05 INSPECTION |
|
| 10/11/2005 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999*ROOM 361 PROVIDE TEST ON TUB THRU OVERFLOW HEIGHT. PROVIDE BRASS DWV MALE ADAPTOR FOR DRAIN ARM AT CAST ?? SANTEE.ROOM 247 SAME. SHUTING TRIP LO?? IS NOT CORRECT TEST |
|
| 10/10/2005 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999*SHALL PROVIDE BRASS MAKE APPT FOR LAVATORY DIETY ARM SHALL PROVIDE WATER TEST FOR TUB SHOWER ALL THE WAY UP ABOVE THE OVERFLOWS SHALL SECURE TUB & SHOWER ARM UNIT 361 |
|
| 10/01/2005 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :*WATER TEST FOR TUBS IN RM 308 & 323 ARE OK | |
| 09/30/2005 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* PUBLIC RESTROOMS MEN & WOMENS INLOBBY AREA RE OK OK TO BACKFIL & DRY WALL WATER DISTRIBUTION IS OK NOTE: SHALL PROVIDE A WATER TEST ON TUBS WITH NEW SLIP JOINT OVERFLOWS SHALL PROVIDE A HANGER WITHIN 18" OF COUPLINGS ON TUB TRAP ARMS |
|
| 09/18/2005 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) I COULD NOT FIND SUPERINTENDENT OR PLUMBING CONTRACTOR |