Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/30/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 09/28/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL PROTECT PLUMBING AT 1 1/4" OF PLATE SURFACE KITCHEN 2) ONE ROOF PANEL NOT NAILED ON EDN AT 6" ON CENTER SOUTH END OF HOUSE |
|
| 09/23/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS 1, 3 AND 7 FROM 9/20/05 NOT DONE 2) MANY ROOF PANELS NOT NAILED |
|
| 09/20/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) ENTRY DORMER BEARING WALLS CANNOT BEAR ON OSB ONLY. PROVIDE CIRY OF TUCSON APPROVED DETAIL FOR BEARING POINTS 2) TRUSS BRACING MISSING - SEE TRUSS DRAWINGS 3) PROVIDE CIRY APPROVED DETAIL FOR SHEAR WALL 5 TRANSFER TO TRUSSES 4) PORCH COLUMN NOT ANCHORED/CLIPPED PER PLAN 5) PORCH GLUE LAN BEAM NOT BEARING ON PORCH POST 6) HEADERS MUST BEAR ON TRIMMERS 7) NAIL PROTECT PLUMBING WITHIN 1 1/4 " OF PLATE SURFACES 8) TRUSSES NOT BEARING ON MID BEARING POINT STOPPED INSP TOO MANY ITEMS |