Date Description Inspector Results Comments
07/05/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
06/30/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) NAIL BLOCKS AT O.S.B. WHERE MAS STRAPS BROKEN SHEATHING
2) REPLACE VERT IN FRONT GABLE
06/29/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) ROOF MISSING NAILING
2) DRIVE STAPLES FLUSH WITH DECK
3) MAS ANCHORS AT FRONT AND EAST FRONT HOLES IN OSB, NAIL OSB TO BLKS AT HOLES
4) MISSING VERT STUD AT FRONT CABLE