Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM02272

Parcel: 141016990


Addresses:

5916 S STARLING DR


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T05CM02272

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
05/31/2005 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
05/27/2005 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
The under slab plumbing is not per code.| 315*
1) LEAK AT MASTER BATH
2) EXTERNALLY GLUING OF FITTINGS NOT ALLOWED. REPLACE SAN-TEE'S LEAVE OLD FITTINGS ON SITE FOR INSPECTION
3) BRIDGED SEWER NOT ALLOWED SUPPORT ON SOLID BASE
4) REMOVE SHADE MATERIAL FROM ALL FITTINGS FOR INSPECTION