Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
| Date |
Description |
Inspector |
Results |
Comments |
| 12/01/2006 |
REINFORCED MASONRY PRE-GROUT |
|
Approved |
INSPECTED COMPRESSED WASHERS FOR POST TENSION WALLS AT SEVERAL LOCATIONS. THIS INSPECTION PLUS THE PAHCOMETER REPORTS IS ACCEPTABLE FOR CODE COMPLIANCE. |