Permit: T05CM02246

Parcel: 10825007D


Addresses:

2010 E RIVER RD

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
11/29/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
CORRECTIONS MADE OK
OK TO COVER ALL AREAS
11/27/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
- TEST ON DWV OK
- PROVIDE 18" OF METALLIC PIPING AT WH
- REMOVE EXCESS FLUX W/DAMP RAG PER UPC INSTALLATION
STANDARDS.
- CORRECT LEAK ON SHOWER PAN
11/20/2006 PLUMBING - INTERMEDIATE Partial Approval CORRECTIONS MADE OK ON FIRST FLOOR
OK TO COVER FIRST FLOOR ONLY
TUBS OK
CLOSET FLANGES OK
11/13/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
- WATER PIPE SIZING NOT PER PLAN.
- OK TO REDUCE AT WH AND AT METER AS WELL AT WASHER BOXES, BUT PIPING SHALL BE FULL SIZE PER PLAN AT THOSE LOCATIONS.
- FOAM WRAP BELOW SLAB REPAIRS.
- SEE NOTES FROM PREVIOUS INSP. REGARDING:
1. SHOWER VALVE ADAPTOR FITTINGS
2. SWEEPS REQUIRED ON TRAP ARMS
RETEST DWV AFTER CORRECTING.
3. TEST TO FLOOD RIM OF TUBS & SHWRS
4. 1ST FLOOR CLOSET FLANGES. SEE 15 9 UPC
10/26/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
- CHECK WATER PIPE SIZING AT 1 1/4 X 3/4 REDUCER. FULL SIZE REQUIRE TO INLET AT WH. PROVIDE WATER METER SIZE SPECS FROM ARCHITECT. SUPPORT TRAP ARM IN EXCESS OF 3'
- SWEEPS REQUIRED AT HORIZONTAL CHANGE OF DIRECTIONS ON TRAP ARMS AND DRAINS.
- SIZE OF ADAPTORS AT PEX CONNECTION TO SHOWER DIVERTERS DOES NOT APPEAR TO BE CORRECT. PROVIDE FITTING SPECS AND LISTING IF DESIGNED FOR 1/2" CONNECTION.
- FASTEN CLOSET RINGS TO FLOOR PER UPC AND LISTING.
- TEST TUBS AND SHOWER PANS TO FLOOD LEVEL
- SOFTENER DRAIN REQUIRES AIR GAP.
- ABS DWV IS UNDER TEST THROUGH ROOF
- OVERHEAD WATER PIPING OK, OK TO BUILD SOFFITS.
10/24/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
09/22/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
NOTE: YOUR ROUGH SOIL HAS ONLY PARTIAL APPROVAL
09/19/2006 PLUMBING - INTERMEDIATE Cancelled