Permit: T05CM02221

Parcel: 140376600


Addresses:

6865 S HARRIER LP

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
07/28/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
P3 SHEAR WALL NOT NAILED AT 3" 0.6 AT HOLD DOWN STUDS
07/27/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
07/26/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ITEMS 1, 6 AND 7 FROM 7/20/05 NOT DONE
07/25/2005 EXT METAL CLIPS/EXT SHEATHING Cancelled CANCELLED PER TIM K.B. HOMES #907-6040
07/25/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
07/22/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NOTHING DONE FROM 7/20/05 INSPECTIONS
07/20/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SHEARWALL P-3 NOT NAILED AT 3" ON CENTER
2) DBL 2 X 6 TRIMMERS MUST SUPPORT GLUE LAM BEAM-TO SHORT
3) P-2 SHEARWALL REQUIRES NAILS AT 4" ON CENTER AND 3/8" FROM EDGE ALSO AT RIBBON ABOVE
4) 7/SD3 NOT COMPLIED WITH AT 54" ON CENTER
5) CLIP GABLE END TRUSSES ON ENDS PER 1/SD3
6) CS20 STRAPS REQUIRED AT 32" ON CENTER
7) CLIP HEADERS TO KING STUDS
8) WIND BRACES MUST BE IN OPPOSITE DIRECTIONS
9) ROOF NOT NAILED
07/18/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) NOT READY PER JEANNE