Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/28/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* P3 SHEAR WALL NOT NAILED AT 3" 0.6 AT HOLD DOWN STUDS |
|
| 07/27/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 07/26/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS 1, 6 AND 7 FROM 7/20/05 NOT DONE |
|
| 07/25/2005 | EXT METAL CLIPS/EXT SHEATHING | Cancelled | CANCELLED PER TIM K.B. HOMES #907-6040 | |
| 07/25/2005 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* | |
| 07/22/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NOTHING DONE FROM 7/20/05 INSPECTIONS |
|
| 07/20/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHEARWALL P-3 NOT NAILED AT 3" ON CENTER 2) DBL 2 X 6 TRIMMERS MUST SUPPORT GLUE LAM BEAM-TO SHORT 3) P-2 SHEARWALL REQUIRES NAILS AT 4" ON CENTER AND 3/8" FROM EDGE ALSO AT RIBBON ABOVE 4) 7/SD3 NOT COMPLIED WITH AT 54" ON CENTER 5) CLIP GABLE END TRUSSES ON ENDS PER 1/SD3 6) CS20 STRAPS REQUIRED AT 32" ON CENTER 7) CLIP HEADERS TO KING STUDS 8) WIND BRACES MUST BE IN OPPOSITE DIRECTIONS 9) ROOF NOT NAILED |
|
| 07/18/2005 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY PER JEANNE |