Permit: T05CM02219

Parcel: 140376630


Addresses:

6877 S HARRIER LP

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
12/20/2005 FRAMING Approved IVRS - Inspection :*
12/19/2005 FRAMING Partial Approval IVRS - Inspection :*
1) A/C WIRES NOT NAILED PROTECTED-WIRES LESS THAN 1 1/4" TO PLATE SURFACE-REPEAT ITEM
2) A REFEE HAS BEEN IMPOSED, YOU HAVE 5 DAYS TO PAY REFEE
12/16/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FIREPLACE FIRE STOP/? NOT INSTALLED PER INSTALLATION MANUAL FIGURE 34. REMOVE INSULATION CENTER DUCTWORK IN CHASE AND INSTALL FIRESTOP SPACER PROVIDE 2" CLEARANCE TO WOOD
2) REMOVE INSULATION FROM TOP PLATE AREAS WHERE WIRES PENETRATE TOP AND BOTTOM WALL PLATES. INSTALL NAIL PROTECTION AS NECESSARY
3) USE ONLY SV4.5HF
3) SPACER COLLAR ONLY FOR FIREPLACE INSTALLATION
12/12/2005 FRAMING Cancelled CANCELLED PER TIM OF K.B. HOMES #907-6040
12/08/2005 FRAMING Denied IVRS - Inspection :
A reinspection fee has been assessed for this inspection. Multiple inspection
Secure wires within 8" of electric box
Seal second floor penetration
Provide water test of tub-install seal
F-3 trusses not bearing at mid point
Fireplace vent seal plate not installed per figure 17 of installation manual
Nail protect wires within 1 1/4" of stud plate surface
You have 5 days to pay a reinspection fee
12/07/2005 FRAMING Cancelled IVRS - RI canceled
12/06/2005 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) NO DWV WATER TEST
2) NO GAS PRESSURE TEST
3) 1" CLEARANCE REQUIRED TO COMBUSTIBLE ABS PLUMBING AT WATER HEATER VE?T
4) INTERIOR BEARING WALLS NOT BEARING TRUSSES
5) INTERIOR BEARING WALLS REQUIRE DBL TOP PLATES
6) STOPPED INSPECTION-NEXT FAILURE WILL REFEE
12/05/2005 FRAMING Cancelled CANCELLED PER TIM OF K.B. HOMES #907-6040
11/28/2005 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) CS20 STRAPS MISSING IN GARAGE SHEARWALL 1/SD2
2) GAS LINE NOT COMPLETE AT FIREPLACE
3) 1" CLEARANCE REQUIRED TO COMBUSTIBLES MATERIAL AT WATER HEATER
4) STOPPED INSPECTION
5) SUPERINTENDENT TO INSURE HOUSE IS COMPLETE PER PLAN AND CODE PRIOR TO NEXT INSPECTION