Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/20/2005 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 12/16/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS 1 AND 3 OF 12/14/05 NOT DONE |
|
| 12/14/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 4" CLEARANCE REQUIRED BETWEEN WEEP SCREED AND SOIL 2) A/C PLATFORMS MUST BE 3" ABOVE GRADE 3) PROVIDE 5 PERCENT GRADE FOR 5 FEET FROM HOUSE 4) TRIM CLEANOUTS TO GRADE 5) SEAL GARAGE CEILING AT WATER HEATER 6) STAIR HANDRAIL MUST BE 36" PLUS OR MINUS 2" ABOVE STAIR AND PARALLEL WITH STAIR 7) STAIR HANDRAIL REQUIRES 1 1/2" GAP TO WALL 8) DUCT WORK KINKED AT NORTH AIR HANDLER. PROVIDE ONE DUCT DIAMETER RADIUS 9) CONVENIENCE OUTLET REQUIRED AT DINING ROOM PONY WALL |