Permit: T05CM02215

Parcel: 140378460

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
12/08/2005 FRAMING Approved IVRS - Inspection :*
12/07/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LEAK AT LAUNDRY STACK
12/06/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
12/02/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SUPPORT HORIZONTAL DWV AT 4' ON CENTER PITCH 1/4" FT
2) SEAL SECOND FLOOR PENETRATIONS
3) SUPPORT GAS LINE AT 10' ON CENTER
4) FIRE STOP W/H "B" VENT AT TOP CHASE
5) TRUSS H2.5 MISSING FRONT BEDROOM
6) MIS-ALIGNED DWV Y ABOVE KITCHEN ENTRY
7) W/B "B" VENT REQUIRES 1" TO COMBUSTIBLE MATERIAL
8) SECOND FLOOR DWV NOT PLUMBED PER PLAN. BUILD TO PLAN OR REVISE PLAN