Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/08/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 12/07/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LEAK AT LAUNDRY STACK |
|
| 12/06/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 12/02/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SUPPORT HORIZONTAL DWV AT 4' ON CENTER PITCH 1/4" FT 2) SEAL SECOND FLOOR PENETRATIONS 3) SUPPORT GAS LINE AT 10' ON CENTER 4) FIRE STOP W/H "B" VENT AT TOP CHASE 5) TRUSS H2.5 MISSING FRONT BEDROOM 6) MIS-ALIGNED DWV Y ABOVE KITCHEN ENTRY 7) W/B "B" VENT REQUIRES 1" TO COMBUSTIBLE MATERIAL 8) SECOND FLOOR DWV NOT PLUMBED PER PLAN. BUILD TO PLAN OR REVISE PLAN |