Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T05CM02211

Parcel: 140377240


Addresses:

5863 E HACKLE LN

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
08/17/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
08/15/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) PORCH POST MISSING
2) OK TO DRY IN HOUSE
08/12/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PORCH POSTS MISSING
2) ITEM 10 OF 8/8/05 NOT DONE
08/08/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GARAGE DOOR KING STUDS NOT CLIPPED
2) CLIP POSTS
3) 3050 KING STUDS NOT CLIPPED
4) NAIL DBL STUDS WITH HOLDOWN AT 4" ON CENTER
5) REAR P-2 SHEAR NOT NAILED
6) REAR DECK NOT ON
7) DECK PATIO DOOR KING STUDS NOT CLIPPED
8) 2ND FLOOR SILL PLATE MUST BEAR 2/3 ON FIRST FLOOR EAST WALL
9) TRIPPLE 2 X POST TO SHORT
10) PROVIDE DBL 2 X POSTS UNDER GIRDER TRUSSES TO GROUND
11) DRAG TRUSS NOT PER 6A/SD3 W/8D AT 6" ON CENTER