Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/20/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 12/19/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FHA STRAPS REQUIRE 6 NAILS ON EACH END 2) 16D NAILS-TWO LOCATIONS AT GAS LINE PENETRATIONS 3) OK TO INSULATE |
|
| 12/16/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SUPPORT GAS LINE AT 10' ON CENTER 2) P-2 DOES NOT COMPLY WITH NOTE "C" PAGE S-1 3) P-3 SHEAR DOES NOT COMPLY WITH NOTE "C" PAGE S-1 4) INSTALL FHA STRAPS ON OVER BORED DBLE TOP PLATES GARAGE AND PANTRY GAS 5) NAIL PROTECT A/C COPPER LAUNDRY 6) SEAL FLOOR PENETRATIONS |
|
| 12/14/2005 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) GAS LINE NOT PER PLAN PROVIDE AS BUILT PLAN SIZED FOR ADDED 30 LF ON RUN 2) 1634 HOUSE 2015 PLAN 3) PROVIDE PROOF THAT "NEW PLAN" IS TD 15-44-86 4) PLUMBING OUT OF WALL LAUNDRY 5) NO GAS PRESSURE TEST 6) ABANDONDED ABS RISER HAS SCREW DAMAGE 7) LEAK AT TUB 8) STOPPED INSPECTION |