Permit: T05CM02203

Parcel: 137061470


Addresses:

334 W CANADA ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/30/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
05/29/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEDIMENT TRAP REQUIRED AT WATER HTR
2) CAP REQUIRED AT FUTURE GAS LINE TO FURNACE
3) HEAT PUMP OVERFUSED
4) DRAFT STOP REQUIRED AT WATER HTR FLUE
5) CAP REQUIRED AT FUTURE DRYER GAS LINE
6) GAS BOND OUTSIDE GARAGE MUST CONTACT BARE STEEL
7) INSTALL VACUUM BREAKERS AT ALL HOSE BIBS
8) DIVERT CONDENSATE DRAIN AWAY FROM CONDENSOR UNIT
9) STUCCO INTERFERING WITH DRYER EXHAUST
10) STOPPED INSPECTION