Permit: T05CM02197

Parcel: 140376050


Addresses:

6900 S GOSHAWK DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/18/2005 FRAMING Approved IVRS - Inspection :*
10/13/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LIVING ROOM SHEARWALL G-1 NOT BUILT PER PLAN. HAVE ENGINEER OF RECORD RE-DESIGN WALL FOR UNDERSIZE PLUMBING WALL
2) 2/SD2 BLOCKS MUST BE 24" MINIMUM
3) MASTER BATH W/C REQUIRES 15" TO C/L
4) SECURE SHOWER VALVE
5) DRYER VENT T CAP CANNOT HAVE MESH GRILL
6) PROVIDE 1" CLEARANCE W/H B-VENT TO 220 CABLE
10/12/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
1) NOT READY PER JEANNE
10/10/2005 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) NO DWV WATER TEST
2) NO GAS PRESSURE TEST
3) SUPPORT HORIZONTAL DWV AT 4' ON CENTER
4) REAR P-1 SHEARWALL REQUIRES ANCHOR BOLTS AT 16" ON CENTER
5) STOPPED INSPECTION-NEXT FAILURE WILL RESULT IN REFEE
10/07/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
09/20/2005 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
HOUSE MUST BE LATHED FOR INTERMEDIATE INSPECTIONS
09/19/2005 FRAMING Cancelled IVRS - RI canceled