Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/06/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 10/05/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) OK TO INSULATE 2) IMPROPER WIRE SPLICE IN LOFT 4 X 4 BOX |
|
| 10/04/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHEAR BLOCK PANELS NOT NAILED PER PLAN 2) NO WATER HEATER VENT 3) FIREBLOCK ? CLOSET 4) WATER HEATER B-VENT REQUIRES 1" TO COMBUSTIBLE 5) SECURE SPLICED WIRE LEFT WITH MECHANICAL FASTENER 6) WIRES MUST HAVE SHEATHING IN OBX AT LEAST 1/4" 7) FIRE BLOCK KITCHEN ARCH 8) NO DRYER VENT |
|
| 10/03/2005 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* |